迅达,电梯,300P,500P,7050,7030,故障代码

发布时间 : 星期四 文章迅达,电梯,300P,500P,7050,7030,故障代码更新完毕开始阅读

1019 IVXVF Reserve19

1020 Line1010 Instruction Emulation 1021 Line1111 Instruction Emulation 1022 HW Breakpoint 1023 FP protocol violation 1024 Format error 1025 Reserved interrupt 1026 Autovector 1 1027 Autovector 2 1028 Autovector 3 1029 Autovector 4 1030 Autovector 5 1031 Autovector 6 1032 Autovector 7 1033 FP Reserved 1034 FP Br Unord 1035 FP Inexact Result 1036 FP Div Zero 1037 FP Underflow 1038 FP Operand Error 1039 FP Overflow 1040 FP Signaling NAN

1041 FP Unimplemented DataType 1042 MMU Reserved

1043 MMU Config error 1044 MMU Illegal Operation 1045 MMU Access Level Violation 1046 TPU Interrupt 1047 SCI Interrupt 1048 SPI Interrupt 1049 CPM Interrupt 1050 External H-Reset 1051 PowerUpReset 1052 WatchdogReset 1053 DoubleBusFaultReset 1054 ClockLossReset 1055 External S-Reset 1056 BErr Released Write 1057 BErr Prefetch 1058 BErr Operand Read 1059 BErr Operand Write 1060 BErr MoveMultiple 1061 BErr Exception Processing 1062 DeadTask 1063 Group24vFail 1064 Lift24vFail 1065 12vPowerFail 1066 BatteryCharging

1067 BatteryLow50 1068 BatteryLow25

1069 BatteryDeadOrMissing 1070 LiftIdSwitchInvalid 1071 MissingEB 1072 SavedRegisters

LON 、SIO错误显示:1200 ... 1399:1201 PowerUpReset 1202 Exception68332 1203 ExtReset1 1204 DeadTask 1205 WdogReset 1206 MysteryReset 1207 NiInitFail 1208 NewNodeFound 1209 MissingNode 1210 NiErrLogged 1211 NodeErrLogged 1212 SvcPinEvent 1213 NiReset 1214 DupLocID 1215 NiErrCounter 1216 DiffCksGP_Konf 1217 DiffCksIO_Konfl

(返回顶部)

1218 TmoCksGP_Konf 1219 TmoDatGP_Konf 1220 TmoCksIO_Konf 1221 TmoDatIO_Konf 1222 DnLdGP_Konf 1223 DnLdIO_Konf 1224 CksErrGP_Konf 1225 CksErrIO_Konf 1226 DoubleReset 1227 HWisLCTRL 1228 NiNoInAppBuf 1229 NiNoInNetBuf 1230 PmipNoOutQ 1231 PmipIqOverflow 1232 SubsystemStart1 1233 SybsystemDead 1234 VcomUpcall 1235 KonfWipe 1236 CadiReset 1237 VcomAllDied 1238 KonfTableFullb 1239 TelTrap 1240 LonDistQfull 1241 LonPupXON

1242 LonDownNACK 1243 LonErr43 1244 LonErr44 1245 LonErr45 1249 NodePowerFail

300P SKE 板

T1: as控制柜 RKPH

T2 井道/底坑 JHSG KBA KNT KUSSA KSSBV KSSBVG KTSG KWS MR(机房) KHA KSSM

T3 轿顶 DREC-U/D ETSL JHC JHCT JREC KF KNA KNE KSSC 井道/底坑 KBV KBVG KNE—U/D KP KPG T4 厅门 KTS

MR(机房) JRH JHM T5 轿厢 KTC 厅门 KV

SKE印板中有以下诊断特性 LRSK-E

绿色LED亮:表示安全电路继电器的状态 关于RF RF1 RSK RSK1 的SW开关 LRTSC

绿色LED亮:表示KTS(厅轿门)的继电器的状态 (厅轿门接点地软件开关) LRTRT

绿色LED亮:表示用于RTRT(门触发继电器)轿厢低速时对门接点进行跨接地软件开关 LRFE-E

绿色LED亮:表示运行触发继电器地接通RFE地软件开关LRFE

绿色LED亮:表示运行触发与RSK RSK1 RF RF1 一起协调启动运行LRSK1 LRSK 绿色LED亮:表示安全电路接通SH和抱闸电源,检查RFE的断电 LRF1 LRF

绿色LED亮:表示运行继电器接通SH和抱闸电源 ULCK

绿色LED亮:表示安全电路的供电状态