迅达,电梯,300P,500P,7050,7030,故障代码

发布时间 : 星期四 文章迅达,电梯,300P,500P,7050,7030,故障代码更新完毕开始阅读

456 SW-Warning56 460 SW-Warning60 461 SW-Warning61 462 SW-Warning62 463 SW-Warning63 464 SW-Warning64 465 SW-Warning65 466 SW-Warning66 467 SW-Warning67 468 SW-Warning68 469 SW-Warning69 470 SW-Warning70 471 SW-Warning71 472 SW-Warning72 473 SW-Warning73 474 SW-Warning74 475 SW-Warning75

马达控制错误显示:600 ... 799: (返回顶部) PVF

General Information about PVF errors

600 Attempt to start not allowed 禁止启动 601 Attempt to restart not allowed 禁止再启动 602 Overtemperature 过热 603 SW warning SW 警告

604 DL overvolt trigg DL 过压触发 605 DL overvolt DL 过压

606 DC link undervoltage DC 电压过低

607 Control Hardware command wrong 控制硬件命令错误

608 Charging DC link failure DC 环充电失败

609 Discharging DC link failure DC 环放电失败 610 Current loop not OK 电流环不正常

611 Deactivate current loop failure 关闭电流环失败 612 Input contactor failure 输入接触器故障 613 Charge contactor failure 充电接触器故障 614 Current difference warning 电流误差警告 615 SW encoder warning SW 编码警告 616 Over current warning 过流警告 617 Over speed warning 过速警告 618 Start direction wrong 启动方向错误 619 Speed reference warning 速度参考值警告 620 Time control motor exceeded 电机控制超时 621 Receive uart failure UART 接受失败 622 Message source failure 消息源故障

623 Message length failure 消息长度错误

624 Receive state wrong 接受状态错误 625 Transmit state wrong 发送状态错误 626 EPROM checksum failure EPROM 检验失败 627 RAM failure RAM 故障

628 Board battery failure 电池故障 629 RAM checksum failure RAM 校验失败 630 Watchdog failure 看门狗故障 631 Transmit failurea631 传送错误 632 Open safety circuit 安全回路开

633 HW encoder warning HW 编码警告

634 Exception vector 矢量异常

635 Contactor time exceeded 接触器超时 636 Driver Print power failure 驱动板电源故障 637 Overtemperature brake resistor 制动电阻过热 638 FCR no start 639 FCR no stop 640 FCR interrupt 641 External error 642 PCC failurea642 643 Supply failure cc1

644 Input contactor failure cc1 645 Charge contactor failure cc1 646 DL overvolt trigg cc1 647 Current difference warn cc1 648 Current loop failure cc1 649 Overtemperature cc1 650 External error cc1 651 Supply failure cc2

652 Input contactor failure cc2 653 Charge contactor failure cc2 654 DL overvolt trigg cc2 655 Current difference warn cc2 656 Current loop failure cc2 657 Overtemperature cc2 658 External error cc2 659 Supply failure cc3

660 Input contactor failure cc3 661 Charge contactor failure cc3 662 DL overvolt trigg cc3 663 Current difference warn cc3 664 Current loop failure cc3 665 Overtemperature cc3 666 External error cc3 667 Dummy 1 668 Dummy 2 669 Dummy 3

See also(返回顶部) Severity Definitions for PVF Display on PVF board PVEC/PIOVEC 700 Memory Failure 701 SW Warning

联系合同范文客服:xxxxx#qq.com(#替换为@)