全自动生化分析仪贝克曼AU680仪器报警列表中文报警翻译

发布时间 : 星期二 文章全自动生化分析仪贝克曼AU680仪器报警列表中文报警翻译更新完毕开始阅读

报警表

3038 3039 3212 Power Failure Detect Reagent Refrigerator Temp. out of Range R1 Reagent Run Out R1 Reagent Empty Probe Detergent Short Probe Detergent Empty ReagentProbeW2DetergentShort R2 Reagent Short R2 Reagent Run Out R2 Reagent Empty R2 Probe W2 Detergent Short ReagentRefrigeratorCover Open STAT Table Large Cover Open STAT Table Small Cover Open Reagent Bottle Switch ReagentShort for RB/ACAL/QC STAT Sampling Interrupt Reagent Refrigerator On Use RB/ACAL Sample Prior Diluent Short Check the Tip of Sample Probe Check the Tip of Reagent Probe Sample Syringe Prime Incomplete ISE Cover Open ISE Buffer Solution Short ISE MID Solution Short ISE REF Solution Short ISE Detergent Short ISE Serum Standard Solution H Short ISE Serum Standard Solution L Short ISE Electrode Check Liquid Na Short ISE Electrode Check Liquid K Short ISE MID Solution Stability Error Sample ID Barcode Error Reagent ID Barcode Error DI Water Empty Detergent (Concentrated) Empty Detergent Empty Sample Probe (FA) Error (Up-Down) Reagent Probe (FD) Error (Up-Down) Detergent Overflow ISE Data Low 电源出现断电 试剂冰箱温度超出范围 R1试剂耗尽 R1试剂空 探针清洗液少了 探针清洗液空了 试剂针W2清洗液少了 R2试剂少了 R2试剂耗尽 R2试剂瓶空 R2探针W2清洗液少了 试剂冰箱盖打开了 急诊仓大盖子打开了 急诊仓小盖子打开了 试剂瓶改变 试剂少,不足以定标、质控 急诊仓取样中断 试剂冰箱正在使用 空白/定标预稀释液缺少 检查样本针尖 检查实际针尖 样本注射器灌注未完成 电解质盖打开 电解质缓冲液少 电解质中值液少 电解质内标液少 电解质清洗液少 电解质血清高值标准液少 电解质血清低值标准液少 钠电极检查液少了 钾电极检查液少了 电解质中值效期错误 样本条码错误 试剂条码错误 去离子水桶空了 浓缩清洗液桶空了 清洗液空了 样本针上下错误 试剂针上下错误 清洗液溢出 电解质数据低 3213 3214 3215 3216 3217 3218 3219 3222 3223 3225 3226 3230 3232 3233 3234 3235 3240 3241 3243 3250 3251 3252 3253 3254 3255 3256 3259 3260 3265 3301 3302 3500 3501 3502 3503 3504 3506 3509

3510 3511 3512 3513 3514 3515 3516 3517 3519 3521 3522 3524 3526 3533 3534 3535 3536 3537 3538 3539 3540 3542 3543 3544 3546 3547 3548 3549 3550 3551 3601 3604 3605 3606 3607 3608 3641 3642 Sample Probe Detergent Empty Sample Prior Diluent Run Out Sample Prior Diluent Empty R1 Reagent Run Out R1 Reagent Empty Reagent Probe Detergent Empty R2 Reagent Run Out R2 Reagent Empty Reagent Refrigerator Cover Open STAT Table Large Cover Open STAT Table Small Cover Open ISE Cover Open Rack Transfer Cover Open Rack Storage Unit Full Rack Storage Unit Full STAT Sampling Interrupt Rack Kind Error Rack ID Barcode Error (A) Rack Supply Unit Cover Open Sample Probe (FA) Error (Liquid Sensor) Reagent Probe (FD01) Error (Liquid Sensor) Reagent Refrigerator Cover Open Reagent Refrigerator Cover Open R2 Reagent Refrigerator Cover Open STAT Table Large Cover Open STAT Table Large Cover Open ISE Cover Open ISE Cover Open ISE A/D Unit Error DI Water Supply Unavailable Rack Transfer Cover Open Unremoval Rack in Rack Supply Unit Unremoval Rack on Rack Transfer (A) Unremoval Rack in Rack Buffer Unit (A) Unremoval Rack in Repeat Run Line (A) Rack Storage Unit Full Rack Supply Unit (CA) Error (A)[A, B, C, D] Rack Supply Belt (CB) Error (A)[A, B, C, D] 样本探针清洗液空了(W1) 样品预稀释液耗尽 样品预稀释瓶空了 R1试剂耗尽(不足) R1试剂瓶空了 试剂探针清洗液空了 R2试剂耗尽(不足) R2试剂瓶空了 试剂冰箱盖打开 急诊仓大盖子打开 急诊仓小盖子打开 电解质盖子打开 架子传输部位盖子打开 架子回收单元满了 架子回收单元满了 急诊台吸样中断 架子类型错误 架子条码错误 架子申请单元的盖子打开了 样品针液体传感器错误 试剂针液体传感器错误 试剂冰箱盖打开 试剂冰箱盖打开 R2试剂冰箱盖打开 样本针向下吸样时急诊台大盖子打开 样本针旋转时急诊台大盖子打开 样本针旋转时ISE盖子打开 分析仪初始化时ISE盖子被打开 ISE进行反应时,A/D信号转化发生错误 (去离子水桶的感应阀出现错误)水位达不到 架子传送带的盖子打开 进架单元架子不能动 架子传送单元架子不能动 缓冲单元进架错误,即架子不能动 复查单元,架子无法动 架子回收单元满了() 架子单元发生错误 架子传送带运行中发生错误

3663 3664 3665 5002 5003 5004 5005 5006 5007 5008 5009 5010 5011 5014 5017 5018 5031 5032 5033 5093 5101 5103 5105 5107 5108 5109 5110 5111 5112 5114 5115 5201 5202 5203 5251 5252 5253 5301 5302 5303 RB Incomplete ACAL Incomplete QC Incomplete INITIALIZE WARM UP STANDBY MEASURE START NO MORE SAMPLE RACKS MOVING TO PAUSE MOVING TO STOP MODE PAUSE STOP SYSTEM END PHOTOCAL START PHOTOCAL END PHOTOCAL FAILURE INDEX UPDATED INDEX DELETED REACTION DATA DELETED PASSWORD CHANGE FAILURE (A) NO REAGENT BOTTLE REAGENT ID READ ERROR REAGENT ID NOT DEFINED R2 REAGENT FOUND IN THE R1 REFRIGERATOR R1 REAGENT FOUND IN THE R2 REFRIGERATOR (A, B, C) ILLEGAL BOTTLE TYPE ILLEGAL REAGENT POSITION REAGENT EXPIRED DIFFERENT LOT NO. REAGENT FOUND REAGENT TYPE CONVERTED BOTTLE TYPE CONVERTED PHOTOCAL DATA ERROR CUVETTE MEAN CHECK ERROR PHOTOCAL LAMP CHECK ERROR INCUBATION BATH TEMPERATURE HIGH INCUBATION BATH TEMPERATURE LOW REAGENT REFRIGERATOR TEMPERATURE HIGH PANIC VALUE (A, B, C, D) HbA1c PRETREATMENT CHECK RANGE ERROR HbA1c% CALCULATION FAILED 空白定标未完成 定标分析未完成 质控未完成 初始化 预热 待机 测量开始 没有样本架 转换成暂停 转换成停止 暂停 停止 系统停止 光电检查开始 光电校正结束 光电校正失败 校正索引 删除索引 删除反应数据 密码修改失败 没试剂瓶 试剂条码阅读错误 未定义试剂条码 在R1试剂仓发现R2试剂 在R2试剂仓发现R1试剂 不规则的试剂瓶 不规则的试剂位置 试剂失效 试剂类型改变 瓶子类型改变 光电数据错误 比色杯均值检查错误 光电灯泡检查错误 反应仓温度过高 反应仓温度过低 试剂冰箱温度过高 达到病理值 糖化预处理范围检查错误 糖化计算错误

5304 5305 5306 5307 5308 5309 5310 5311 5312 5313 5314 5315 5317 5401 5402 5403 5404 5408 5751 5752 5753 6010 6031 6032 8001 8003 8100 9000 NO COLOR DATA NO BLANK DATA RB DATA ERROR CALIBRATION FACTOR RANGE OVER CALIBRATION FACTOR RANGE UNDER CALIBRATION OD RANGE OVER CALIBRATION OD RANGE UNDER CALIBRATION ERROR MULTIPOINT-CAL. OD SLOPE CHECK ERROR 1/2 POINT-CAL. CORRECTION FACTOR ERROR QC DATA RANGE OVER QC DATA RANGE UNDER QC DATA DEVIATION CHECK ERROR NO SAMPLE CUP (A, B-C, D) SAMPLE NOP (A, B-C, D) SAMPLE ID NOT FOUND NO TESTS REQUISITIONED SAMPLE ID READ ERROR PRINTER NOT SELECTED PRINTER NOT AVAILABLE PART OF DATA IS NOT OUTPUT YET FAILED TO DELETE SAMPLE (A) ONLINE ERROR ONLINE FORMAT ERROR DPR-ANL COMMUNICATION ERROR (A, B) DPR-ANL COMMUNICATION TIMEOUT PRINTER ERROR PROGRAM ERROR (***) 无颜色实验数据 无空白实验数据 试剂空白数据错误 定标因数范围超上限 定标因数范围超下限 定标吸光度范围超上限 定标吸光度范围超下限 定标错误 多点定标吸光度斜率检查错误 一点/两点校准因数错误 质控数据范围超上限 质控数据范围超下限 质控数据产生偏差 没有样本杯 没有申请样本 未找到样本条码 未申请测试 样本条码阅读错误 未选择打印机 打印机不可用 部分数据暂未输出 删除标本失败 数据传输错误 数据格式错误 数据分析传输错误 数据通信超时 打印错误 程序错误

联系合同范文客服:xxxxx#qq.com(#替换为@)