扣件式脚手架计算书

发布时间 : 星期一 文章扣件式脚手架计算书更新完毕开始阅读

第一种情况

由可变控制的组合:

N5=1.2×[G1k+(G2k+G3k)×h]×la×lb+1.2×H×gk+1.4×[(Qk+κQk)×la×lb+0.6×Nwk]

=1.2×(0.2+(24+1.1)×350×0.001)×0.9×0.8+1.2×3.3×0.176+1.4×((2+1.35×0.5)×0.9×0.8+0.6×0.134)=11.268kN

由永久荷载控制的组合:

N6=1.35×[G1k+(G2k+G3k)×h]×la×lb+1.35×H×gk+1.4×[0.7×(Qk+κQk)×la×lb+0.6×Nwk]

=1.35×(0.2+(24+1.1)×350×0.001)×0.9×0.8+1.35×3.3×0.176+1.4×(0.7×(2+1.35×0.5)×0.9×0.8+0.6×0.134)=11.517kN

N=max(N5,N6)=max(11.268,11.517)=11.517kN Υ0×N/(φA) f=205N/mm2

=1×11.517×1000/(0.231×4.89×100)=102.089N/mm2

满足要求

第二种情况

由可变控制的组合:

N7=1.2×[G1k+(G2k+G3k)×h]×la×lb+1.2×H×gk+1.4×(Qk+κQk)×la×lb =1.2×(0.2+(24+1.1)×350×0.001)×0.9×0.8+1.2×3.3×0.176+1.4×(2+1.35×0.5)×0.9×0.8=11.156kN

由永久荷载控制的组合:

N8=1.35×[G1k+(G2k+G3k)×h]×la×lb+1.35×H×gk+1.4×0.7×(Qk+κQk)×la×lb =1.35×(0.2+(24+1.1)×350×0.001)×0.9×0.8+1.35×3.3×0.176+1.4×0.7×(2+1.35×0.5)×0.9×0.8=11.404kN

N=max(N7,N8)=max(11.156,11.404)=11.404kN

Υ0×N/(φA)+Υ0×Mw/W=1×11.404×1000/(0.231×4.89×100)+1×0.002×1000/5.08=101.472N/mm2≤f=205N/mm2

页脚

满足要求

七、可调托座验算

按上节计算可知,可调托座受力N=12.164kN≤[N]=30kN

满足要求

八、架体抗倾覆验算

根据《建筑施工脚手架安全技术统一标准》(GB51210)中6.2.17条规定,我们计算抗倾覆时按最不利工况考虑,即架体上无集中堆放物料,抗倾覆力矩仅考虑模板支架及附件自重和顶部模板等物料自重。

则抗倾覆判断公式如下:

架体自重:GZ=H×gk=3.3×0.176=0.58kN

因:GZ /(la×lb)+G1k=0.58/(0.9×0.8)+0.2=1.006kN/m2

3Υ0×MTk/[(n×lb)2×la]=3×1×1.002/((6×0.8)2×0.9)=0.145kN/m2 故:GZ/(la×lb)+G1k>3Υ0×MTk/[(n×lb)2×la]

满足要求

页脚

联系合同范文客服:xxxxx#qq.com(#替换为@)