KPI性能工作总结V1 联系客服

发布时间 : 星期日 文章KPI性能工作总结V1更新完毕开始阅读

发现失败为传输资源不可用导致的失败。 ? 解决措施

需要传输侧解决传输闪断问题。

? 效果评估

传输解决后,指标恢复正常

E-RAB建立成功起始时间 小区 总次数 09/17/2014 00:00:00 09/17/2014 01:00:00 09/17/2014 02:00:00 09/17/2014 03:00:00 09/17/2014 04:00:00 09/17/2014 05:00:00 09/17/2014 06:00:00 09/17/2014 07:00:00 09/17/2014 08:00:00 09/17/2014 09:00:00 09/17/2014 10:00:00 09/17/2014 11:00:00 09/17/2014 12:00:00 09/17/2014 13:00:00 09/17/2014 14:00:00 09/17/2014 15:00:00 09/17/2014 16:00:00 09/17/2014 17:00:00 09/17/2014 18:00:00 09/17/2014 19:00:00 09/17/2014 20:00:00 09/17/2014 21:00:00 09/17/2014 22:00:00 CCCC_襄樊路_HLH_F21_1 CCCC_襄樊路_HLH_F21_1 CCCC_襄樊路_HLH_F21_1 CCCC_襄樊路_HLH_F21_1 CCCC_襄樊路_HLH_F21_1 CCCC_襄樊路_HLH_F21_1 CCCC_襄樊路_HLH_F21_1 CCCC_襄樊路_HLH_F21_1 CCCC_襄樊路_HLH_F21_1 CCCC_襄樊路_HLH_F21_1 CCCC_襄樊路_HLH_F21_1 CCCC_襄樊路_HLH_F21_1 CCCC_襄樊路_HLH_F21_1 CCCC_襄樊路_HLH_F21_1 CCCC_襄樊路_HLH_F21_1 CCCC_襄樊路_HLH_F21_1 CCCC_襄樊路_HLH_F21_1 CCCC_襄樊路_HLH_F21_1 CCCC_襄樊路_HLH_F21_1 CCCC_襄樊路_HLH_F21_1 CCCC_襄樊路_HLH_F21_1 CCCC_襄樊路_HLH_F21_1 CCCC_襄樊路_HLH_F21_1 1 1 7 1 2 1 4 38 60 33 92 97 82 171 92 120 65 41 24 25 21 16 14 E-RAB建立尝试总次数 1 1 7 1 2 1 4 38 60 33 92 97 82 171 92 120 65 41 24 25 21 16 14 E-RAB建立成功率 100.00% 100.00% 100.00% 100.00% 100.00% 100.00% 100.00% 100.00% 100.00% 100.00% 100.00% 100.00% 100.00% 100.00% 100.00% 100.00% 100.00% 100.00% 100.00% 100.00% 100.00% 100.00% 100.00% 3. 无线掉线率

1) 用户增多导致掉线率恶化的分析处理

? 问题描述:

从9月14日至9月17日长春城区无线掉线率较高,平均掉线率为0.6%;14日之前无线掉线率平均为0.44%,掉线率恶化了0.16%。

? 问题分析

初步定位,全网掉线率指标恶化主要因为以下6个小区:CCCC_动画学院_HLH_V_D17_3、CCCC_工院教学楼_HLH_F15_1、CCCC_工院教学楼_HLH_F15_3、CCCC_吉大经信_HLH_F17_1、CCCC_卫星路华苑_HLH_F17_1、CCCC_长春大学综合楼1公寓2D区长春大学东区图书馆900六教900_HLW_E27_4。

以上小区上周平均每天6-18点共掉线23266次;而近三天,平均每天6-18点掉线70276次,较上周平均每天6-18点增加了47010次,主要是由于用户增多导致的掉线,影响全网掉线指标。

下面根据用户数量及掉线情况进行了比较,当用户数增多后掉线数量增多、掉线率恶化,如下图所示,趋势基本一致 1、CCCC_工院教学楼_HLH_F15_3小区

小区内的平均用户数160140120100806040200 UE Context异常释放次数35000300002500020000150001000050000 无线掉线率12.00.00%8.00%6.00%4.00%2.00%0.00%

2、CCCC_动画学院_HLH_V_D17_3小区